单片机

STM32F0多路ADC采样中的BUG和解决方案

分类:单片机 发布:2019-03-20 10:47:16 浏览:454次 Tag:

uint32_t ADC_Detect(uint32_t  AD_Channel)  

{  

  

    hadc.Instance->CHSELR = 0;  

    ADC_ChannelConfTypeDef sConfig;  

    sConfig.Channel = AD_Channel;  

        sConfig.Rank = ADC_RANK_CHANNEL_NUMBER;  

        sConfig.SamplingTime = ADC_SAMPLETIME_1CYCLE_5;  

        HAL_ADC_ConfigChannel(&hadc, &sConfig);  

    

    uint32_t ADC_result;  

    /*ADC START*/  

        if(HAL_ADC_Start(&hadc)!=HAL_OK)  

    {  

        while(1)  

        {  

        }  

    }  

    /*Wait for ADC completed*/  

    if (HAL_ADC_PollForConversion(&hadc, 10) != HAL_OK)  

  {  

     while(1)  

      {  

      }  

  }  

  else  

  {  

    /*Get the converted value of regular channel*/  

    ADC_result = HAL_ADC_GetValue(&hadc);  

        HAL_ADC_Stop(&hadc);  

        //ADC_result =((ADC_result*3300)>>8);  

        return ADC_result;  

  }  

}  

使用CUBE生产的ADC无法配置多路采样,多路采样采集值不对,研究后发现是底层函数没有将CHANNEL清零导致的


只需要在函数中增加 hadc.Instance->CHSELR = 0; 手动清0 寄存器即可。 